Cathodic protection for steel in concrete
Cathodic protection stops reinforcement corrosion by passing a small, controlled current to the steel, so it no longer corrodes. It is the only technique proven to stop corrosion in chloride-contaminated concrete, which is why it is used on many of Australia's most important marine and transport structures.
Our team has around 40 years of experience in cathodic protection of reinforced concrete, and was involved in developing Australian Standard AS 2832.5 for cathodic protection of steel in concrete structures.
Our cathodic protection services
Condition assessment
Corrosion surveys, chloride and carbonation testing, potential mapping and resistivity testing to confirm whether CP is the right solution.
CP system design
Impressed current (ICCP), galvanic and hybrid anode systems designed to AS 2832.5 for each structure and exposure zone.
Specification and trials
Technical specifications, trial applications to verify the design, and support through tendering.
Installation supervision
On-site supervision, quality assurance testing and commissioning of new systems.
Testing and maintenance
Scheduled performance testing, depolarisation measurements and yearly inspections in line with AS 2832.5. About our CP testing
Remote monitoring
24/7 monitoring and remote adjustment through our Cathodic Protection Management System (CPMS).
Structures we protect
- Wharves, jetties and port infrastructure
- Road and rail bridges
- Sea walls and coastal structures
- High-rise and strata buildings
- Car parks and balconies
- Heritage and historic structures
Experience on landmark structures
Our team's experience includes the cathodic prevention system for the Sydney Opera House broadwalk support structure, the cathodic prevention system installed during construction of Sea Cliff Bridge, impressed current cathodic protection for wharves at the Port of Brisbane, and cathodic prevention for the Hangzhou Bay Bridge in China.
Already have older CP systems? See our CP system audits and upgrades.
Common questions
What is the difference between ICCP and galvanic cathodic protection?
Impressed current systems (ICCP) use a power supply to deliver a controlled current and suit large structures and high corrosion activity, such as marine tidal and splash zones. Galvanic systems use sacrificial anodes that need no power supply and suit lower corrosion activity or patch repairs.
Which Australian Standard applies to cathodic protection of concrete?
AS 2832.5 covers the design, installation, commissioning and monitoring of cathodic protection systems for steel in concrete structures.
Do you work outside Sydney?
Yes. We provide cathodic protection services across Australia, both on site and through remote monitoring.